Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
J. vasc. bras ; 23: e20220137, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1534798

ABSTRACT

Abstract The purpose of this systematic review is to evaluate the safety of pre-endovascular abdominal aortic aneurysm repair (EVAR) embolization of aortic side branches - the inferior mesenteric artery and lumbar arteries. Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines were followed. A search of MEDLINE and DIMENSION databases identified 9 studies published from 2011 to 2021 that satisfied the inclusion and exclusion criteria. These studies were analyzed to detect the incidence of embolization-related complications. A total of 482 patients underwent preoperative aortic side branch embolization, 30 (6.2%) of whom suffered some kind of minor complication. The only major complication observed was ischemic colitis in 4 (0.82%) patients, two (0.41%) of whom died after bowel resection surgery. Regarding these findings, aortic side branch embolization seems to be a safe procedure, with very low percentages of both minor and major complications.


Resumo O objetivo desta revisão sistemática foi avaliar a segurança da embolização de artéria mesentérica inferior (AMI) e artérias lombares (ALs) pré-correção endovascular de aneurisma da aorta abdominal. Foram realizadas pesquisas nas bases de dados MEDLINE e Dimensions. Foram encontrados 9 estudos publicados de 2011 a 2021 que atendiam aos critérios de inclusão e exclusão. Os estudos foram analisados ​​para definir a incidência de complicações relacionadas à embolização. No total, 482 pacientes foram submetidos a embolização de AMI e/ou ALs, dos quais 30 (6,2%) sofreram algum tipo de complicação menor. A única complicação importante observada foi colite isquêmica em 4 (0,82%) pacientes. Dois (0,41%) desses pacientes morreram após cirurgia de ressecção intestinal. Em relação a esses achados, a embolização de AMI e ALs parece ser um procedimento seguro, com um percentual muito baixo de complicações menores e importantes.

2.
Journal of Medical Biomechanics ; (6): E472-E478, 2023.
Article in Chinese | WPRIM | ID: wpr-987973

ABSTRACT

Objective To study the effects of aneurysmal neck angle on stent displacement after endovascular repair of abdominal aortic aneurysm (AAA). Methods The CT images of 28 patients were selected to establish preoperative AAA model, postoperative AAA model and covered stent model respectively, and the models were divided into non-severe angulation group ( n = 14) and severe angulation group ( n = 14) according to the preoperative angle of tumor neck. The geometric shape of each model was measured, and the changes of AAA geometric parameters and postoperative stent displacements before and after surgery were analyzed. The displacement force of the model during the first follow-up was calculated by hemodynamic simulation. Results Significant differences were found in tumor length, maximum diameter, displacement force, tumor neck length and tumor volume between two groups of patients (P 0. 05). For the incidence of internal leakage, there were 2 cases in non-severe angulation group and 4 cases in severe angulation group (P>0. 05).Conclusions Severe neck angulation can lead to a significant increase in support displacement force and decrease in proximal anchorage zone, and thus increase the possibility of support displacement. It is suggested that doctors should strengthen postoperative follow-up for patients with severe neck angulation and be vigilant of the occurrence of long-term internal leakage in clinic.

3.
Japanese Journal of Cardiovascular Surgery ; : 114-117, 2023.
Article in Japanese | WPRIM | ID: wpr-965970

ABSTRACT

A 77-year-old woman underwent endovascular abdominal aortic repair (EVAR) for an abdominal aortic aneurysm (AAA).Five years after surgery, she visited the hospital with the chief complaint of a fever. Enhanced computed tomography (CT) showed enlargement of the AAA around the stent-graft and a mass, which was suspected to be an abscess, outside the aneurysm. A blood test revealed a high level of inflammatory response. The patient was diagnosed with infectious AAA. She received antibiotics; however, the inflammatory response did not completely improve. A second CT scan revealed that the suspected abscess had a spreading tendency. The patient was referred to our hospital for a highly suspected stent-graft infection. We performed Y-graft replacement using a rifampicin-immersed graft, and as much as possible of the wall around the aortic aneurysm was removed. The inflammatory response improved rapidly after the operation, and the patient was discharged 15 days later. According to the results of a pathological examination, a diagnosis of xanthogranulomatous inflammation and fibrosis was made. Here, we report a rare case of xanthogranulomatous inflammation of the aortic aneurysm wall after EVAR.

4.
Japanese Journal of Cardiovascular Surgery ; : 235-239, 2022.
Article in Japanese | WPRIM | ID: wpr-936681

ABSTRACT

Concomitant occurrence of coronary arterial disease (CAD) with abdominal aortic aneurysm (AAA) is not rare. Combined performance of open surgery (OS) of AAA repair and coronary arterial bypass grafting (CABG) has been reported to be effective as the way to avoid the risk of rupture of the aneurysm and acute coronary syndrome (ACS), while it's highly invasive. We successfully performed a combination performance of endovascular aneurysm repair (EVAR) and off-pump CABG (OPCAB) with the support of an intra-aortic balloon pump (IABP) in 2 cases with AAA and unstable angina pectoris (UAP). It was suggested that this strategy is a reasonable clinical option for the patient with UAP complicated with large AAA.

5.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 726-730, 2022.
Article in Chinese | WPRIM | ID: wpr-995513

ABSTRACT

Objective:To explore the value of fusion imaging in the treatment of complex aortic pathology.Methods:A retrospective analysis was conducted of 29 patients with complex aortic pathology who underwent treatment with endovascular aortic repair using fusion imaging (FI+ ) technique or without FI (FI-) between June 2015 and June 2021. The perioperative outcomes and morbidity of the FI was assessed and the early results of follow up were evaluated.Results:The mean age of patients was (70.3±7.3) years old, and 24 (82.8%) males. Technical success was 96.5% (28/29). The FI+ group patients had lower procedure time[FI+ , (209±53) min vs. FI-, (306±24)min, P=0.005]and ionic contrast medium[(169±23)ml vs. (201±20)ml, P=0.040]. Contrast-induced acute kidney injury (CI-AKI)[3.4%(FI+ 0 vs. FI-6.7%, P=0.33)], and operation-related reintervention[6.9%(FI+ 0 vs. FI-13.3%, P=0.16)] were similar. There were no significant differences in blood loss, fluoroscopy time. Conclusion:FI technique improves the accuracy during positioning in complex endovascular aortic repair, could reduce aortic related reintervention rate, operation time and contrast dose. Further studies and development are needed to obtain optimal image quality and higher precision.

6.
J. vasc. bras ; 20: e20200093, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1346433

ABSTRACT

Resumo Contexto O ultrassom contrastado por microbolhas (CMUS) é uma modalidade diagnóstica de acurácia bem demonstrada por estudos internacionais para seguimento de reparo endovascular do aneurisma de aorta abdominal (EVAR). Não existem, no entanto, estudos nacionais focados nesse método de seguimento. Objetivos O objetivo deste estudo foi relatar a experiência inicial com CMUS em um hospital terciário, traçando uma comparação dos achados do CMUS com o ultrassom Doppler convencional (USGD), com o intuito de verificar se a adição de contraste ao protocolo padrão de controle ultrassonográfico incorreu alteração nos achados. Métodos Entre 2015 e 2017, 21 pacientes em seguimento de EVAR foram submetidos ao USGD seguido de CMUS. Foram avaliados os achados de exame referentes à identificação de complicações, bem como à capacidade de identificação da origem da endofuga. Resultados Entre os 21 casos avaliados, 10 complicações foram evidenciadas no total: sete pacientes apresentaram endofuga (33,3%); dois pacientes apresentaram estenose em ramo de endoprótese (9,52%); e um paciente apresentou dissecção em artéria ilíaca externa (4,76%). Em 21 pacientes avaliados, o uso combinado dos métodos identificou 10 casos de complicações pós-EVAR. Em seis dos sete casos de endofugas (85,71%), o uso dos métodos combinados foi capaz de identificar a origem. O USGD isolado falhou na identificação da endofuga em dois casos (28,5%), identificando achados duvidosos em outros dois casos (28,5%), que obtiveram definição diagnóstica após associação do CMUS. Conclusões O CMUS é uma técnica de fácil execução, a qual adiciona subsídios ao seguimento de EVAR infrarrenal.


Abstract Background Microbubble contrast enhanced ultrasound (CEUS) is an accurate diagnostic method for follow-up after endovascular abdominal aortic aneurysm repair (EVAR) that has been well-established in international studies. However, there are no Brazilian studies that focus on this follow-up method. Objectives The objective of this study was to report initial experience with CEUS at a tertiary hospital, comparing the findings of CEUS with those of conventional Doppler ultrasound (DUS), with the aim of determining whether addition of contrast to the standard ultrasonographic control protocol resulted in different findings. Methods From 2015 to 2017, 21 patients in follow-up after EVAR underwent DUS followed by CEUS. The findings of these examinations were analyzed in terms of identification of complications and their capacity to identify the origin of endoleaks. Results There was evidence of complications in 10 of the 21 cases examined: seven patients exhibited endoleaks (33.3%); two patients exhibited stenosis of a branch of the endograft (9.52%); and one patient exhibited a dissection involving the external iliac artery (4.76%). In the 21 patients assessed, combined use of both methods identified 10 cases of post-EVAR complications. In six of the seven cases of endoleaks (85.71%), use of the methods in combination was capable of identifying the origin of endoleakage. DUS alone failed to identify endoleaks in two cases (28.5%) and identified doubtful findings in another two cases (28.5%), in which diagnostic definition was achieved after employing CEUS. Conclusions CEUS is a technique that is easy to perform and provides additional support for follow-up of infrarenal EVAR.


Subject(s)
Humans , Male , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/surgery , Ultrasonography, Doppler/instrumentation , Contrast Media , Microbubbles , Endovascular Procedures , Follow-Up Studies , Aortic Aneurysm, Abdominal/rehabilitation , Aortic Aneurysm, Abdominal/diagnostic imaging , Ultrasonography, Doppler/methods
7.
Japanese Journal of Cardiovascular Surgery ; : 69-72, 2021.
Article in Japanese | WPRIM | ID: wpr-873940

ABSTRACT

Leg malperfusion accompanied with type B acute aortic dissection (AAD) is reported to be an independent predictor for mortality. In such a case, though aortic replacement, extra anatomical arterial bypass or endovascular aortic repair (EVAR) can be selected, an appropriate treatment strategy has not been established yet. A 53-year-old woman was urgently hospitalized with sudden low back pain and right leg weakness, despite the right popliteal and anterior tibial arteries being palpable. Computed tomography (CT) revealed a type B AAD, and antihypertensive therapy was initiated. She complained of intermittent claudication during rehabilitation, and right leg ischemia with decreased ankle brachial pressure index (ABPI) was detected. The follow-up CT revealed the narrow true lumen of the right common iliac artery compressed by the thrombosed false lumen and the large entry of the aortic dissection in the terminal aorta. At the subacute phase of the aortic dissection, EVAR was performed. To expand the true lumen and exclude the entry, Y-shaped stent-grafts were implanted in the infra-renal aorta and the bilateral common iliac arteries. The postoperative course was uneventful. Postoperative ABPI returned to the normal range, and the intermittent claudication disappeared. In conclusion, EVAR should be considered in patients with type B AAD complicated with leg malperfusion.

8.
Japanese Journal of Cardiovascular Surgery ; : 69-72, 2019.
Article in Japanese | WPRIM | ID: wpr-738315

ABSTRACT

We report a case of mycotic aneurysm treated with endovascular aneurysm repair (EVAR). An 80-year-old man was admitted to a local hospital with high fever and lower back pain. Pyogenic spondylitis and psoas muscle abscess were diagnosed. Klebsiella pneumoniae was confirmed by blood culture. Treatment with intravenous antibiotics was not effective and contrast computed tomography (CT) scan showed an enlargement of the abscess and an abdominal aortic rupture. The patient was immediately transferred to our hospital. Laboratory tests showed an elevated C-reactive protein (12.3 mg/dl) and WBC (10,400/μl). Mycotic abdominal aneurysm rupture was diagnosed by CT scan. He underwent an emergency EVAR with an Excluder® (aorta extender). Intraoperative angiography showed a ruptured abdominal aorta. After operation, he was treated with intravenous minocycline and ampicillin, and the size of the abscess reduced without any endoleak on enhanced CT imaging. After intravenous antibiotics therapy for 4 weeks, we switched to oral antibiotics (minocycline and ciprofloxacin) and continued them for 6 months. As of 2 years after the surgery, there are no signs of infection or recurrence.

9.
J. vasc. bras ; 17(1): 66-70, jan.-mar. 2018. graf
Article in English | LILACS | ID: biblio-894152

ABSTRACT

Abstract Despite technological advances, the long-term outcomes of endovascular aortic aneurysm repair (EVAR) are still debatable. Although most endograft failures after EVAR can be corrected with endovascular techniques, open conversion may still be required. A 70-year-old male patient presented at the emergency unit with abdominal pain. Twice, in the third and fourth years after the first repair, a stent graft had been placed over a non-adhesive portion of the stent graft due to type Ia endoleaks. In the most recent admission, a CT scan showed type III endoleak and ruptured aneurysm sac. On this occasion the patient underwent late open conversion. The failure was repaired with total preservation of the main endovascular graft body and interposition of a bifurcated dacron graft. This case demonstrates that lifelong radiographic surveillance should be considered in this subset of patients. Late open conversion following EVAR of ruptured abdominal aortic aneurysms can be performed safely.


Resumo Apesar dos avanços tecnológicos, os desfechos de longo prazo do reparo endovascular de aneurismas da aorta abdominal (endovascular aortic aneurysm repair - EVAR) ainda são objeto de debate. Embora a maioria das falhas de endoenxerto após EVAR possam ser corrigidas com técnicas endovasculares, conversão para cirurgia aberta ainda pode ser necessária. Um paciente de 70 anos de idade, do sexo masculino, apresentou-se no serviço de emergência com dor abdominal. Duas vezes, dois e quatro anos após o primeiro reparo, um enxerto foi colocado sobre uma porção não adesiva do stent devido a endoleak tipo Ia. Na mais recente hospitalização, a tomografia computadorizada mostrou endoleak tipo III e ruptura de um saco aneurismático. Nesta ocasião, o paciente foi submetido a conversão tardia para cirurgia aberta. A falha foi tratada com preservação total do corpo principal do enxerto endovascular e interposição de um enxerto tipo Dacron bifurcado. Este caso demonstra que a vigilância radiográfica ao longo de toda a vida deveria ser considerada nesse subgrupo de pacientes. Conversão tardia para cirurgia aberta após EVAR de aneurismas rotos da aorta abdominal pode ser realizada com segurança.


Subject(s)
Humans , Male , Aged , Aortic Rupture/surgery , Aortic Aneurysm, Abdominal/surgery , Conversion to Open Surgery , Prostheses and Implants , Radiological Surveillance , Endoleak/diagnostic imaging , Endovascular Procedures
10.
Braz. j. med. biol. res ; 51(9): e6864, 2018. tab, graf
Article in English | LILACS | ID: biblio-951754

ABSTRACT

The mortality of patients with mycotic aneurysms is high, especially in East Asia, and infection by Salmonella species is the most common. Our study aimed to improve prognosis of adult mycotic aneurysms with early diagnosis and accurate treatment. Four adult patients with mycotic aneurysm caused by Salmonella were included and analyzed by single-center retrospective analysis. Cases reported in the literature during the past 10 years were also summarized. The average age of the 4 male patients was 61.25 years, while that of the 53 cases reported in the literature was 65.13 years. Hypertension, diabetes, and atherosclerosis were common complications. Most patients presented fever and experienced pain at the corresponding position of the aneurysm. Laboratory examination found an increased number of white blood cells accompanied by an increase in inflammatory markers. Most aneurysms were found in the abdominal aorta, while the rupture of an aneurysm was the most common complication. The mortality rates were 21.43 and 7.14% after open surgery or endovascular aneurysm repair (EVAR) intervention, respectively. The recurrence rates of infection were 0 and 17.85% for both treatments, respectively. The mortality rate of mycotic aneurysm caused by Salmonella infection was high in middle-aged males with hypertension, diabetes, and atherosclerosis. The possibility of a Salmonella-infected aneurysm should be considered in these high-risk groups presenting chills, fever, chest, and back pain. Open surgery was superior to EVAR treatment in the clearance of infected foci and the reduction of postoperative recurrence. The recurrence of postoperative infection can be prevented by intravenous antibiotic therapy for 6 weeks post-surgery.


Subject(s)
Humans , Male , Middle Aged , Salmonella Infections/complications , Aneurysm, Infected/microbiology , Aortic Aneurysm, Thoracic/microbiology , Salmonella/isolation & purification , Salmonella Infections/mortality , Salmonella Infections/diagnostic imaging , Aneurysm, Infected/mortality , Aneurysm, Infected/diagnostic imaging , Tomography, X-Ray Computed , Risk Factors , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/drug therapy , Aortic Aneurysm, Thoracic/diagnostic imaging , Anti-Bacterial Agents/therapeutic use
11.
Japanese Journal of Cardiovascular Surgery ; : 298-302, 2018.
Article in Japanese | WPRIM | ID: wpr-688473

ABSTRACT

A 92 year-old-female with melena was admitted to our hospital. She underwent Y-graft replacement of the abdominal aorta at the age of 65. Gastroduodenal fiberscopic examination and computed tomography (CT) confirmed the diagnosis of aortoduodenal fistula. The fistula in the proximal anastomotic site was occluded with a suture ligature and omentopexy was performed. On the 15th post-operative day she developed high-grade fever. CT revealed a pseudoaneurysm formation at the proximal anastomosis site. She underwent emergency endovascular aneurysmal repair (EVAR). Her postoperative course was uneventful. She is doing well without symptoms of recurrent infection.

12.
Clinics ; 70(6): 435-440, 06/2015. tab, graf
Article in English | LILACS | ID: lil-749795

ABSTRACT

OBJECTIVES: To analyze angiotomographic parameters of juxtarenal aneurysms to assess the applicability of an endograft model to patients and to create in vitro and in vivo models to assess the new endograft. METHODS: A total of 49 patients with juxtarenal aneurysms were submitted to angiotomographic evaluation, and parameters such as the aortic diameter, the length of the neck, and the angulations of the celiac trunk, superior mesenteric artery and renal arteries; the distances between them; and anatomic variations were analyzed. Based on these parameters, an endograft model was developed and tested in a newly created in vitro model of juxtarenal aneurysm. An experimental model of juxtarenal aneurysm was then established in six pigs weighing 50-60 kg to assess the new endograft model. RESULTS: The angiotomographic parameters of juxtarenal aneurysm measured in this study were similar to those reported in the literature and allowed the development of an endograft based on the hourglass concept, which was applicable to 85.8% of the patients. The in vitro model of juxtarenal aneurysm evidenced good radiopacity and functionality and permitted adjustments in the new device and technical improvements in the procedures for treating these aneurysms. In addition, the porcine model of juxtarenal aneurysm was successfully created in all six animals using a bovine pericardial patch, and use of the new endograft in three pilot procedures evidenced its feasibility. CONCLUSIONS: The Hourglass endograft was rendered applicable to treatment of the majority of patients with juxtarenal aneurysms simply by changing its diameter. Moreover, the new in vitro and in vivo models were shown to be effective for assessing both the presented endograft and experiments assessing the endovascular treatment of juxtarenal aneurysms. .


Subject(s)
Animals , Cattle , Humans , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Endovascular Procedures/methods , Prosthesis Design , Aorta/anatomy & histology , Aortic Aneurysm, Abdominal/diagnosis , Blood Vessel Prosthesis Implantation/methods , Models, Animal , Neck/anatomy & histology , Pilot Projects , Renal Artery/anatomy & histology , Stents , Swine
13.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 3451-3453,3454, 2015.
Article in Chinese | WPRIM | ID: wpr-602591

ABSTRACT

Objective To analyze the effect of EVAR in the treatment of octogenarian patients with abdomi-nal aortic aneurysm.Methods 16 octogenarian patients aged over 80 years who treated with EVAR were collected. Mean age was (87.0 ±6.2)years and included 11 cases in male,2 cases in emergency.All the cases were infrarenal abdominal aortic aneurysm and 11 cases (69%)were the complex aortic anatomy.According to ASA classification, 11 cases (69%)were class Ⅲ and 5 cases (31%)were class Ⅳ.All patients were followed up with CT for 1 month to 3 years.We evaluated technical success rate,perioperative complications and the application characteristics of EVAR in the treatment of octogenarian patients with abdominal aortic aneurysm were analyzed.Results All the patients were operated with EVAR,the success rate was 100%,12 Endurant endografts and 4 Talent endografts were used.Mean operation time was (92 ±25)min and mean hospital stay length was (17 ±9.5)days.1 patient died with heart failure in 3 days after operation.1 patient died due to the Ⅰ endoleak and 4 patients died due to other fators. Conclusion For the octogenarian abdominal aortic aneurysm patients,EVAR is the preferred treatment with accepta-ble procedural success and perioperative morbidity.Those patients have characteristics in the physiological function and anatomy,so we should take measures to prevent the complications.The medium and long -term results suggest that EVAR may be of limited in some patients who are aged over 80 years.

14.
Japanese Journal of Cardiovascular Surgery ; : 301-306, 2015.
Article in Japanese | WPRIM | ID: wpr-377498

ABSTRACT

<b>Objective</b> : Although an endoleak is the most common complication after endovascular abdominal aortic aneurysm repair (EVAR), the proper and noninvasive method for the detection of endoleaks is not established. The purpose of this study is to investigate whether plasma levels of D-dimer and fibrin degradation product (FDP) could be predictors of endoleaks after EVAR. <b>Methods</b> : Between June 2011 and January 2014, 65 consecutive patients underwent EVAR at our institution. We evaluated 55 patients excluding 10 patients pre-existing conditions such as aortic dissection, arterial or venous thrombosis, conversion to open surgery, and difficulties in making outpatient visits. Enhanced computed tomography (CT) examination was performed during 12 months after EVAR. Persistent endoleaks and maximum aneurysmal diameter were evaluated at each follow-up time. Patients were divided into groups according to CT findings at 12 months after EVAR. There were 26 patients with endoleaks vs. 29 non-endoleak patients, 34 with unchanged aneurysm findings vs. 21 with shrinkage. No patient showed aneurysmal enlargement. Plasma levels of D-dimer, FDP, counts of platelet, prothrombin time (PT), and activated partial thromboplastin time (APTT) were also measured at the time of CT examinations. <b>Results</b> : There was no operative death and no major complication. Endoleaks in all patients were identified as type II. None of them required re-intervention. In the endoleak group, plasma levels of D-dimer and FDP were significantly higher than in the non-endoleak group in each postoperative period. In addition, postoperative counts of platelet were significantly lower in the endoleak group. PT and APTT test results showed no significant difference in the two groups. In the unchanged aneurysm group, postoperative D-dimer and FDP tended to be higher compared with the shrinkage group. Postoperative counts of platelet also tended to be lower in the unchanged group. There were no differences in PT and APTT test results. <b>Conclusion</b> : Plasma levels of D-dimer and FDP are potentially useful predictors of endoleaks after EVAR.

15.
Japanese Journal of Cardiovascular Surgery ; : 283-287, 2015.
Article in Japanese | WPRIM | ID: wpr-377174

ABSTRACT

An 81-year-old man who had a saccular abdominal aortic aneurysm (AAA) with a narrow terminal aorta underwent endovascular aortic aneurysm repair (EVAR) with the Medtronic Endurant<sup>®</sup> stent graft system. After 4 days, computed tomography (CT) showed stenosis of the stent graft left limb, which was pressed flat against the right limb at the narrow terminal aorta. We performed re-intervention to dilate the narrow terminal aorta and bilateral limbs with kissing stenting using Express Vascular LD<sup>®</sup> (Boston Scientific). After operation his ankle brachial pressure index rose from 0.88 to 0.99 and there was no evidence of stenotic limbs at CT image. We need to be careful about the stenotic limb after EVAR with Medtronic Endurant stentgraft system for AAA with a narrow terminal aorta.

16.
Japanese Journal of Cardiovascular Surgery ; : 245-248, 2015.
Article in Japanese | WPRIM | ID: wpr-376991

ABSTRACT

We report a case of endovascular aneurysm repair (EVAR) in a patient with an aortocaval fistula (ACF) who presented with congestive heart failure due to left-to-right shunting. The patient was an 80-year-old man who complained of sudden respiratory discomfort and lower leg edema, and was admitted to the emergency department. The initial diagnosis on admission was acute heart failure. Because the inferior vena cava was visualized by angiography in the arterial phase due to the fistula from the abdominal aorta, after admission, we rediagnosed this case as ACF. As medical treatment did not improve the patient's symptoms, emergency surgery was decided upon. Because preoperative evaluation was able to rule out the existence of an aortic aneurysm, ACF closure was performed by EVAR. The postoperative course was uneventful and the patient was discharged 15 days after surgery. ACF without aortic aneurysm is uncommon and is not easily diagnosed. This case demonstrated that EVAR can be an effective treatment option for ACF.

17.
Japanese Journal of Cardiovascular Surgery ; : 165-169, 2015.
Article in Japanese | WPRIM | ID: wpr-376118

ABSTRACT

We report a 90-year-old man with intestinal necrosis of the sigmoid colon after EVAR. His abdominal aortic aneurysm was 7.3 cm in diameter, and mural thrombus was present from the abdominal aortic aneurysm to the proximal common iliac arteries. Because type Ib endoleakage from the right distal edge of the stent graft was present, extension to the iliac bifurcation was performed using an additional leg device. The external iliac artery was severely calcified and tortuous ; thus, insertion of the leg device was technically difficult. Immediately after the operation, abdominal distention, right trash foot, and a small amount of rectal bleeding were observed. The patient was managed conservatively, and the symptoms resolved within a few days. Oral intake was started on postoperative day 5. However, 4 days after the initiation of oral intake, the patient suffered from abdominal pain and fever. Free air was observed by chest X-ray and computed tomography. Emergency laparoscopic examination revealed intestinal necrosis and perforation of the sigmoid colon. Therefore, the sigmoid colon was resected, and a transverse colostomy was performed. The patient recovered relatively well, with oral food intake beginning on day 6 and rehabilitation on day 8. He was discharged in good condition with unaided ambulation 5 weeks after bowel resection. Pathological examination demonstrated ischemic colitis due to cholesterol emboli.

18.
Clinics ; 69(9): 641-646, 9/2014. tab, graf
Article in English | LILACS | ID: lil-725412

ABSTRACT

This systematic review focuses on the 30-day mortality associated with open surgery and fenestrated endografts for short-necked (<15 mm) juxtarenal abdominal aortic aneurysms. A search for studies published in English and indexed in the PubMed and Medline electronic databases from 2002 to 2012 was performed, using “juxtarenal abdominal aortic aneurysm” and “treatment” as the main keywords. Among the 110 potentially relevant studies that were initially identified, eight were in accordance with the inclusion criteria in the analysis. Similar outcomes for open and endovascular repair were observed for 30-day mortality. No differences were observed regarding the secondary outcomes (duration of surgery, hospital stay, postoperative renal dysfunction and late mortality), except that the late mortality rate was significantly higher for the patients treated with open repair after a median follow-up of 24 months. Fenestrated endografting is a viable alternative to conventional surgery in juxtarenal abdominal aortic aneurysms with a proximal neck <15 mm.


Subject(s)
Female , Humans , Male , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Blood Vessel Prosthesis , Statistics, Nonparametric , Treatment Outcome
19.
Japanese Journal of Cardiovascular Surgery ; : 351-356, 2014.
Article in Japanese | WPRIM | ID: wpr-375630

ABSTRACT

The purpose of this case report was to discuss the efficacy of The Amplatzer Vascular Plug (AVP) in endovascular aneurysm repair (EVAR) for ruptured aortoiliac aneurysm. A 73-year-old man was referred to our institution with a diagnosis of ruptured abdominal aortic aneurysm (rAAA) by CT scan. The CT scan showed an rAAA of 70 mm (Fitzgerald classification 3) and a right common iliac aneurysm of 30 mm. The patient was immediately transferred from the ER to the OR and treated with EVAR in combination with occlusion of the right internal iliac artery (IIA) using AVP. The total procedural time was 138 min. The patient recovered uneventfully after the operation with an ICU stay of 2 days and was discharged 9 days after the onset. EVAR has been recognized as a therapeutic option for rAAA in Japan. However, it is not yet been generally adopted as a first-line therapy for rAAA accompanied with iliac aneurysm because of the necessity to occlude IIA. The conventional method with coils to induce thrombosis of IIA is unsuitable for patients in a critical situation for the time required and the difficulty in precise placement. AVP is a nitinol-based self-expanding cylindrical device that is used for arterial embolization. AVP allows assured embolization of IIA in a shorter procedural time, which is essential in an urgent situation. Although AVP is still under post-market surveillance in Japan and only available in limited institutions, the usage of AVP should be considered as an adjunctive procedure in EVAR for rAAA and may expand the limits of endovascular treatment for rAAA.

20.
Japanese Journal of Cardiovascular Surgery ; : 447-451, 2013.
Article in Japanese | WPRIM | ID: wpr-374619

ABSTRACT

A 80-year-old woman was referred to our hospital for coagulation abnormality and huge abdominal aortic aneurysm (AAA). She had persistent hemorrhage from the surgical wound after the operation for her cubital tunnel syndrome 5 days before. Enhanced computed tomography image revealed AAA with a maximum diameter of 91 mm. Laboratory data were compatible with disseminated intravascular coagulation (DIC). Due to the marked hemorrhagic status, we thought the open repair of AAA was an extremely risky procedure. We initiated the medical treatment with gabexate mesilate. However, the hemorrhage continued after 2 weeks of medical therapy. We performed endovascular aneurysm repair (EVAR). DIC improved after the procedure. Postoperative enhanced computed tomography image showed regression of the aneurysm with no endoleak. EVAR might be an acceptable procedure for AAA with DIC.

SELECTION OF CITATIONS
SEARCH DETAIL